Display Shows Water Shortage Protection
Causes and Solutions:
1.Check if the water inlet valve is open and if the water pressure is sufficient and continuous.
2.Check if the ice-making drain is continuously draining water. If so, clean the drain valve or tie a knot in the drain pipe to prevent water from draining out.
Display Shows High Pressure Protection
Causes and Solutions:
3.Check if the water inlet valve is open and if the condenser water pressure is sufficient. It is recommended to connect to a mains water supply.
For air-cooled models, check if the cooling fan is operating normally.
4.If the high-pressure protection is triggered immediately upon startup, short-circuit the two wires on the pressure switch.
For Commercial Ice Machine 650 LBS/24H, 400 LBS Storage Capacity
SKU:7031751/7031754